Connectors & Fasteners

sst-logo_cropped.gif

 

Simpson Strong TieTM ICF Ledger Connectors

 

ICFVL (14 gauge steel)

ICFVL-W (16 gauge steel) w/8, D3 screws ea. use w/SPF ledger

ICFVL-CW (16 gauge steel) w/8, D3 screws ea. use w/LVL ledger

  • Price: $6.15 each
  • QTY: 15 / carton
  • sold by the carton only

 


 

ICF-D3 Screws: 120/pkg

  • Price: $48.
  • QTY: 120 / pkg

 


 

 

simpson_ICFVL.gif   simpson_ICFVL_Wand_CW.gif
ICFVL  

ICFVL-W and ICFVL-CW

 

The ICFVL Ledger Connector System is engineered to solve the challenges of mounting wood or steel ledgers to insulated concrete form (ICF) walls. The ICFVL is designed to provide both vertical and lateral, in-plane performance. There are many benefits over traditional anchor bolting, including better on center spacing in most cases, faster installation and no protrusions.

The embedded legs of the ICFVL are embossed for additional stiffness and the hole allows for concrete to flow through and around the connector. The exposed flange on the face of the ICF provides a structural surface for mounting either a wood or steel ledger.

Material: ICFVL - 14 gauge; ICFVL-CW and ICFVL-W - 16 gauge.

Finish: Galvanized.

Installation: ICFVL in ICF

  • For use with a minimum 4" thick core.
  • Snap a chalk line for the bottom of the ledger.
  • Mark required on center spacing.
  • Use ICFVL to mark kerfs locations.
  • Cut kerfs at marks.
  • Insert ICFVL flush to the face of the ICF.
  • Pour concrete.

Wood Ledger Attachment – ICFVL-W or -CW

  • Slip appropriate ledger connector underneath the ledger.
  • Install the eight ICF-D3 screws partially into the ledger.
  • Position the ledger level to the chalk line and drive the screws through the wood and into the ICFVL.

Steel Ledger Attachment

  • Position the ledger level to the chalk line and against the ICFVL.
  • Attach with four 1/4-14x3/4", #3 drill point screws (not provided).
  • All screws should be located at least 1/2" from the edge of the ICFVL.
  • Space screws evenly.

WARNING: Industry studies show that hardened fasteners can experience performance problems in wet environments. Accordingly, use this product in dry environments only.

These tables address vertical load applications only.

simpson_sm_tablegif.gif

  1. Fasteners for wood ledger (D3) are provided with the part and fasteners for steel ledger are not provided.

  2. Loads apply to ICF foam thicknesses of 2 3/4" or less.

  3. Alternately, #14 x 3/4" fastener may be used.

  4. Tabulated loads may not be increased.

  5. Concrete f'c = 2500 psi minimum.

  6. When combining download and lateral loads, Designer shall evaluate as follows:
       Design Download/Allowable Download + Design Lateral Load/Allowable Lateral Load ≤ 1.

These tables address vertical load applications only.

simpson_lge_tablegif.gif

 

  1. The Designer may specify different spacing based on the load requirements.

  2. Spacings are based on perpendicular to grain capacity of bolt in wood ledger compared to tested value of ICFVL.
    Additional connectors required for out-of-plane loads.

  3. See flier F-ICFVL for additional connection details.

  4. For steel ledgers, the 68 mil ledger spacing is closer than the 54 mil ledger because the calculated load of a bolt is higher in a thicker piece of steel.

  5. Steel ledger values are based on steel. Fu = 60 ksi.

Simpson Installation Manual (pdf)

 